MSA 370

Enclosed Linear Encoder

  • max. measuring length 3040 mm
  • distance coded Reference marks (K)
  • rigid mounting
  • simplest assembly through mounting holes
    on the extrusion ends and with mounting supports

MSA 370

System
resolution
µm

Accuracy
±µm/measuring
length

Grating
pitch
µm

Output
analog (Upp)

 Output
analog (Ipp)

Output
digital
(Subdividing factor)

see *

±3, ±5, ±10

20

MSA 370.03

MSA 370.13

--

see *

±2, ±3

10

MSA 370.01

MSA 370.11

--

10

±10

40

--

--

MSA 370.24 (1)

5

±5, ±10

20

--

--

MSA 370.23 (1)

2

±5

40

--

--

MSA 370.64 (5)

1

±3, ±5

20

--

--

MSA 370.63 (5)

0,5

±3, ±5

20

--

--

MSA 370.73 (10)

0,25

±2, ±3, ±5

10

--

--

MSA 370.71 (10)

0,1

±2, ±3

10

--

--

MSA 370.51 (25)

* = depending on
external Subdividing          
  
Measuring lengths: 70 mm to 3040 mm
Measuring scale: glass scale

Position of the
Reference mark:
(selectable)

MSA 370.xx K:
Distance coded Reference marks (K): after travelling 20 mm the absolute
position will shown on the display.
MSA 370.xx:
Standard: Up to measuring length 920 mm one Reference mark in the middle of the measuring length or 35 mm from both ends of measuring length, measuring
length 1040 mm and longer, 45 mm from both ends of measuring length.
Option: One Reference mark at any location, or two or more RI's separated
by distances of n x 50 mm
Output analog: typical 1 Vpp
Output analog: typical 11,5 µApp
Output digital:

square wave signals (single ended)
with integrated Subdividing Electronics

square wave signals (differential) via Line Driver RS 422 standard
with integrated Subdividing Electronics

 

*Specification subject to change without notice* 

Dimensions and Mounting possibilities:
(Adobe Acrobat 5.0 or higher required)

Document Type Size
 
Mounting Instructions
Mounting Instructions MSA 370 . pdf 533.03 kb 
 
Dimensions, Mounting possibilities
MSA 370 . pdf 430.99 kb 
 
Technical data product-related