MSA 672

Enclosed Linear Encoder

  • two sets of sealing lips for additional contamination protection
  • max. measuring length 2240 mm
  • distance coded Reference marks (K)
  • simplest assembly through mounting holes on the extrusion ends

MSA 672

System
resolution
µm

Accuracy
±µm/measuring
length

 Grating
pitch
µm

Output
analog (Upp)

Output
analog (Ipp)

Output
digital
(Subdividing factor)

see *

±3, ±5, ±10

20

MSA 672.03

MSA 672.13

--

see *

±2, ±3

10

MSA 672.01

MSA 672.11

--

10

±10

40

--

--

MSA 672.24 (1)

5

±5, ±10

20

--

--

MSA 672.23 (1)

2

±5

40

--

--

MSA 672.64 (5)

1

±3, ±5

20

--

--

MSA 672.63 (5)

0,5

±3, ±5

20

--

--

MSA 672.73 (10)

0,25

±2, ±3, ±5

10

--

--

MSA 672.71 (10)

0,1

±2, ±3

10

--

--

MSA 672.51 (25)

* = depending on
external Subdividing
  
Measuring lengths:           70 mm to 2240 mm
Measuring scale: glass scale

Position of the
Reference mark:
(selectable)

MSA 672.xx K:
Distance coded Reference marks (K): after travelling 20 mm the absolute
position will shown on the display.
MSA 672.xx:
Standard: Up to measuring length 920 mm one Reference mark in the middle of the measuring length or 35 mm from both ends of measuring length, measuring
length 1040 mm and longer, 45 mm from both ends of measuring length.
Option: One Reference mark at any location, or two or more RI's
separated by distances of n x 50 mm

Output analog: typical 1 Vpp
Output analog: typical 11,5 µApp
Output digital:

square wave signals (single ended)
with integrated Subdividing Electronics

square wave signals (differential) via Line Driver RS 422 standard
with integrated Subdividing Electronics

 

*Specification subject to change without notice* 

Dimensions and Mounting possibilities:
(Adobe Acrobat 5.0 or higher required)

Document Type Size
 
Mounting Instructions
Mounting Instructions MSA 672 . pdf 532.61 kb 
 
Dimensions, Mounting possibilities
MSA 672 . pdf 422.71 kb 
 
Technical data product-related
MSA 672 . pdf 414.28 kb