MS 40 SERIES

Open Linear Encoder with Single-Field Scanning

  • easy mounting as a result of large monting tolerances
  • high insensitivity to contamination by use of an extensive single-field scanning principle 
  • high traversing speed 
  • "true" reference mark (accurate and repeatable from both traversing directions)
  • integrated subdividing electronics in the encoder head for up to times 100 interpolation (before quadrature)
  • max. measuring length 10.040 mm

MS 40

System
resolution
µm

Accuracy-
grades
±µm/m

Steel tape scale
Grating pitch
µm

Output signal
analog (Vpp)

Output signal
analog (Ipp)

Output signal
digital
(interpolation)

see *

±30

200

MS 40.06

--

--

10

±30

200

--

--

MS 40.66 (5)

5

±30

200

--

--

MS 40.76 (10)

1

±30

200

--

--

MS 40.86 (50)

0,5

±30

200

--

--

MS 40.96 (100)

* = depenting on external Subdividing
 

Standard measuring length:

120 mm to 10,040 mm

Position of the Reference mark:(RI)

standard separated by distances of n x 100 mm

Output analog:

typical 1 Vpp

Output digital:

square wave signals (single ended)
with integrated Subdividing Electronics

square wave signals (differential) via Line Driver RS 422 standard
with integrated Subdividing Electronics
with analog signal switch-over for setup

 
Tape carrier::

MS 40.xx MO = steel tape scale only
MS 40.xx MK = steel tape scale with adhesive tape

MS 40 MOMK overall dimensions

MS 40.xx MP = steel tape scale in aluminium carrier with clamping element, carrier glued

MS 40 MP overall dimensions

 

*Specification subject to change without notice*

Dimensions and Mounting tolerances:
(Adobe Acrobat 5.0 or higher required)

Document Type Size
 
Dimensions, Mounting possibilities
MS 40 MO, MS 40 MK . pdf 91.79 kb 
MS 40 MP . pdf 100.79 kb